Toshiba dk14 manual RCIU/RCIS or RCIU2/RCIS, Rwiu, Rctu, Rsiu

Models: dk14

1 418
Download 418 pages 533 b
Page 55
Image 55
RCIU/RCIS or RCIU2/RCIS

System & Station

Program 03 for DK424 – Flexible PCB Cabinet Slot Assignments

RCIU/RCIS or RCIU2/RCIS

When installing RCIU2/RCIS, enter the Caller ID circuit numbers on the record sheet in place of the CO line number. Each RCIU2/RCIS slot uses eight Caller ID circuits. RCIU2/RCIS circuit numbers are assigned automatically in numerical order (001~200) starting with the lowest slot number, to the highest RCIU2/RCIS slot number in 8-circuit increments.

Important! If more than four circuits are needed, never install an RCIU without an RCIS.

On DK424, RCIU2/RCIS can be installed in any universal slot except slot 11 or if RSIU is installed, slot 12; they do not have to be installed adjacent to corresponding CO lines. Refer to Program *50 to manually assign RCIU2/RCIS circuits to CO line circuits.

RWIU

Code 61 must be set for all RWIU slots including slots that are vacant because they support RWIU channels 09~32.

RCTU

The table below gives you slot locations and PCB Code Assignments for all RCTUs.

Processor

R11 Slot

RCTU Slot

Slot Code

PCB Code

 

 

Cabinet 1

Assignment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCTUA

No

Yes

00

91~94

 

 

 

 

 

 

 

 

 

RCTUB

No

Yes

00

91~94

 

System

 

 

 

 

 

 

RCTUBB

No

Yes

01

91

 

RCTUBA

Yes

No

00

91~94

 

 

 

 

 

 

 

 

&

RCTUC

Yes

No

00

91~94

 

 

Station

 

 

 

 

 

 

RCTUD

No

Yes

01

91~94

 

 

 

 

 

 

 

 

 

 

RCTUE

Yes

No

00

91~94

 

 

 

 

 

 

 

 

 

RCTUF

No

Yes

01

91~94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PCB Codes:

91=No RRCS 92=4 -circuit RRCS 93=8 -circuit RRCS 94=12 -circuit RRCS

Note When using RCTUA, Slot 15 and 16 does not support Speaker OCA or DIU Data Switching. RCTUA does not support ACD, ACD/MIS, RS-232 Voice Mail Integration (SMDI), and attendant console features.

RSIU

If an RSIU is installed in base cabinet slot 11, you must connect the programming station to circuit 6 in slot 12. In this case, a PDKU or PEKU should be installed in slot 12 and Station Port Number 000~007 will be in slot 12.

If an RSIU is not installed, you must connect the programming station to circuit 6 in slot 11 (Port

005)and/or circuit 6 in slot 12 (port 013). The station must be a 20-button digital LCD or electronic LCD telephone. Also, if an RSIU is not installed, install a PDKU or PEKU in slot 11.

Strata DK Programming 5/99