1
1-88 EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
Descriptions of the switch fabric setting fields are as follows:
Domain
The domain number uniquely identifies the switch in a fabric. This 
value is automatically assigned by the Fabric. The range of valid 
values varies depending on the switch model and other system 
parameter settings (refer to VC En coded Address Mode).
BB Credit
The buffer-to-buffer (BB) credit represents the number of buffers 
available to attached devices for frame receipt. The range of allowed 
values varies depending on other system settings.
R_A_TOV
The resource allocation time-out value (R_A_TOV) is displayed in 
milliseconds. This variable works with the variable E_D_TOV to 
determine switch actions when presented with an error condition. 
Allocated circuit resources with detected errors are not released until 
the time-out value has expired. If the condition is resolved prior to 
the time-out, the internal time-out clock resets and waits for the next 
error condition.
E_D_TOV
The error detect time-out value (E_D_TOV) is displayed in 
milliseconds. This timer is used to flag a potential error condition 
when an expected response is not received (an acknowledgment or 
reply in response to packet receipt, for example) within the set time 
limit. If the time for an expected response exceeds the set value, then 
an error condition occurs.
Data Field Size
The data field size specifies the largest possible value, in bytes, and 
advertises this value to other switches in the fabric during 
construction of the fabric, as well as to other devices when they 
connect to the fabric. Setting this to a value smaller than 2112 may 
result in decreased performance.