1
switchdiag 1-429
Telnet Commands
switchdiagRun diagnostics on aDS-32B2 switch.
Syntax switchdiag
Availability Admin
Description Use this command to run a suite of diagnostics tests on the specified
switch. To run this command you must install loopback plugs on
every port. The tests executed are:
◆portregtest
◆centralmemorytest
◆cmitest
◆camtest
◆filtertest
◆statstest
◆portloopbacktest
◆txdpath
◆crossporttest
◆spinsilk
◆backport
◆diagshow
Compared to switchdiagshort, this is a comprehensive test for
switch functionality which also involves backplane connections. The
switch must be disabled to run this command.
Options None
Example To run a suite of diagnostics on a DS-32B2:
switch:admin> switchdiag
Testing: user ports: 3 2 1 0 7 6 5 4 11 10 9 8 15 14 13 12
PortRegTest
Running Port Register Test ....
passed.
Test Complete: "portregtest" Pass 1 of 1
Duration 0 hr, 2 min & 23 sec (0:2:23:443).