1
1-412 EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
Examples This example is for v4.0. To run spinFab on ports 0-4:
switch:admin> spinfab -nmegs 3 -ports 0-4
spinfab running...
spinfab: Completed 3 megs, status: passed.
port 0 test status: 0x00000000 -- passed.
port 1 test status: 0x00000000 -- passed.
port 2 test status: 0x00000000 -- passed.
port 3 test status: 0x00000000 -- passed.
port 4 test status: 0x02000000 -- SKIPPED!
Test...
Diagnostics When it detects failure(s), the test may report one or more of the
following error messages:
0x20 ERR_STAT_ENCIN
0x21 ERR_STAT_CRC
0x22 ERR_STAT_TRUNC
0x23 ERR_STAT_2LONG
0x24 ERR_STAT_BADEOF
0x25 ERR_STAT_ENCOUT
0x26 ERR_STAT_BADOS
0x27 ERR_STAT_C3DISC
0x28 ERR_STAT
0x29 XMIT
0x2a PORT_M2M
0x2b PORT_ABSENT
0x2c PORT_DIED
0x2d PORT_ENABLE
0x2e PORT_STOPPED
0x2f PORT_WRONG
0x30 ERR_STATS_ENCIN
0x31 ERR_STATS_CRC
0x32 ERR_STATS_TRUNC
0x33 ERR_STATS_2LONG
0x34 ERR_STATS_BADEOF
0x35 ERR_STATS_ENCOUT
0x36 ERR_STATS_BADOS
0x37 ERR_STATS_C3DISC
0x38 ERR_STATS
0x3a INIT
0x3b DATA
0x3c NO_SEGMENT
0x39 TIMEOUT
0x3d STATS_FTX
0x3e STATS_FRX