1-64 EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
cfgShow
Display zone configuration information.
Syntax cfgShow ["pattern"[, transflag]
Availability All users
Description Use this command to display zone configuration information.
If no operand is specified, all zone configuration information (both
defined and enabled) is displayed.
If an operand is specified, it is used as a pattern to match zone
configuration names in the defined configuration; those that match
the pattern are displayed.
The defined configuration is the complete set of all zone objects that
have been defined in the fabric. There can be multiple zone
configurations defined, but only one can be enabled at a time. There
may be inconsistencies in the definitions, zones or aliases that are
referenced but not defined, or there may be duplicate members.
The enabled configuration is the currently zone configuration
enabled. The devices that an initiator sees in the fabric are based on
this configuration. The enabled configuration is built when a
specified zone configuration is enabled.
This command requires a Zoning License.