1
1-52 EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
c. Check that all ASIC Y has its:
interrupt bits are set.
error type is chip number error.
the port number in error is the receiver port (which is the
base port of asic Y).
d. Reading the error register clears the CMEM interrupt bit;
ready for the next offset to test.
Operands This command has the following operands. If all are omitted, the
default values used are 1 for passCount,QUAD_RAMP for dataType,
and a random value for dataSeed.
Example To test the ASIC central memory:
switch:admin> centralMemoryTest
Running Central Memory Test ... passed.
Test complete: "centralmemorytest" Pass 1 of 1.
Duration 0 hr, 0 min & 19 sec (0:0:19:500)
passed.
passCount Specify the number of test passes to run. By default
the test will be run one time. The passes parameter
may be used to run the specified number of passes.
dataType Specify the type of data pattern to use. By default,
type 9, QUAD_RAMP is used. For a complete list
of supported data patterns run the dataTypeShow
command. Some common settings are:
1 Byte fill pattern.
2 Word fill pattern.
3 Quad fill pattern.
9 Quad ramp (Addr=Data) pattern.
11 Random data.
dataSeed Specify the data pattern seed to be used. The
default seed value is 0.