1-122 EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
diagsetcycleSet diagnostic script parameters.
Syntax diagSetCycle <script_name> [-show|-default|<-keyword
value>..]
Availability Admin
Description Use this command to update diagnostic command parameters. With
only the script operand specified, this command displays all
configuration variables used by the specified script. Each variable can
be modified. For each variable, the current value, default value, and
description of purpose of the variable are displayed. If no new value
is specified, then the current value is left unchanged. If a new value is
entered, then it is validated, and stored in the configuration database
for that blade type.
The changes implemented by this command are saved to nonvolatile
memory and do not require a reboot to take effect.
Operands This command has the following operands:
script_name Specify the script where you want to modify
the parameters. If no filename is specified, then
this command lists all scripts containing the
keyword DIAGSETCYCLE_CAPABLE. This
operand is optional.
-show Specify this operand to display the parameters
for a selected script file. This operand is
optional.
-default Specify this operand to set the values to the
default.
-keyword value Specify this option to set the value of a specific
keyword (for example, -number_of_runs 3).
This operand is optional.