1
1-438 EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
The switch summary is followed by one line per port:
port number Port number. Valid values vary depending on the
switch type.
module type Port module type (GBIC or other):
◆-- — no module present
◆sw — shortwave laser
◆lw — longwave laser
◆cu — copper
◆id — serial ID
port speed 1 G — 1 G per second fixed transfer speed
2 G — 2 G per second fixed transfer speed
N1 — 1 G per second negotiated transfer speed
N2 — 2 G per second negotiated transfer speed
AN— Auto negotiating
port state ◆Port state information
◆No_Card — no interface card present
◆No_Module — no module (GBIC or other) present
◆No_Light — module not receiving light
◆No_Sync — module receiving light but out of sync
◆In_Sync — module receiving light and in sync
◆Laser_Flt — module signaling a laser fault
◆Port_Flt — port marked faulty
◆Diag_Flt — port failed diagnostics
◆Lock_Ref — locking to the reference signal
◆Testing — running diagnostics
◆Online — port is up and running