![](/images/new-backgrounds/1118152/11815249x1.webp)
The Device View
6C105/6C107 and its installed modules is split 50/50 between the supplies (+/- 5%). The Power Redundancy field displays whether or not the chassis is currently configured for load sharing and power redundancy. Possible values are:
•Available (Green) — Two
•Not Available (Yellow) — Only a single
PS #1/#2 Status
Indicates the state of any power supplies installed in the 6C105/6C107 Chassis. Possible states returned are:
•Not Available (Yellow) — No response has been returned from the device regarding the power supplies.
•Normal (Green) — A power supply is installed and operating in the associated power slot.
•Fault (Red) — The power supply in the associated power slot is not operational.
•Not Installed (Blue) — The indicated power slot is not occupied by a power supply.
Fan Tray Status
The 6C105/6C107 supports a single, removable fan tray that has four fans. The tray is hot swappable, so it can be removed without powering down the chassis. This field indicates the status of the 6C105/6C107 Fan Tray:
•Not Available (Yellow) — No response has been returned regarding the fan tray.
•Normal (Green) — A fan tray is installed and operational.
•Fault (Red) — One or more fans in the tray have failed.
•Not Installed (Blue) — The fan tray slot is not occupied. The chassis is in danger of overheating if it continues to run without the fan tray installed.