The Device View

Line Voltage

Displays the voltage coming through the line attached to the SmartSwitch 6000 or Matrix E7.

Battery Output

Displays the amount of battery output voltage.

Battery Capacity

Displays the percentage of remaining battery capacity (100% indicates a fully charged battery).

Test Results

Displays the result of the last self-test performed by the UPS. The possible test results are:

Unit OK

The UPS unit is in working order.

Unit Failed

The UPS unit has failed the self-test. Check the unit

 

for damage or consult your UPS user’s manual.

Bad Battery

The UPS unit battery is bad.

No recent test

No UPS self-test has been performed in the last five

 

minutes.

Unit in test...

The UPS is currently in test mode.

Please standby

 

Setting the UPS ID

You need to set the UPS ID typecode that indicates the manufacturer and model of the UPS.

To set the UPS ID:

1.Click on the arrow next to the SET UPS ID text box. A Model number menu will appear. Scroll to highlight the appropriate UPS ID. (Consult the manual that was included when you purchased your UPS for the correct Model ID number.)

2.Click on the OK button. The UPS ID you have chosen will appear in the text box, and the UPS window will be active.

If your UPS unit does not function after you have set this ID, check the manual you received with the UPS to ensure that you have chosen the correct UPS ID. If you need to change the ID, follow the directions given above.

Using the Test Option

You can use the test option to activate a self-test cycle for your unit. This self-test will check the viability of your unit and its battery.