Table 27

Troubleshooting Table

 

 

 

 

 

 

Problem

 

 

Solution

 

 

 

 

 

The library is not efficiently

Check the network bandwidth from the host computer.

 

backing up data.

 

Check that the library’s drive(s) are on their own SCSI bus and

 

 

 

 

 

 

 

not daisy-chained to another tape drive or the hard drive.

 

 

 

Check that the server and file system have the processing

 

 

 

 

power and memory needed to stream the tape drive.

 

 

 

Ensure that the drive is clean. (See Cleaning a Drive on

Chapter

 

 

 

page 87.)

 

 

Try a new tape. A marginal tape can cause performance

 

 

 

 

 

 

problems due to bad spots on the tape requiring retries.

4

 

 

 

 

 

 

Ensure that the backup software is using fixed-length records

 

 

 

 

(or blocks) to maximize throughput and has not defaulted to a

 

 

 

 

smaller record size. (64K should be sufficient.)

 

 

 

Ensure that the data is being compressed, however do not turn

 

 

 

 

on both software and hardware compression.

 

 

 

Check the size of the files. Backing up several small files can

 

 

 

 

impact performance.

 

 

 

 

 

 

Operations

 

 

 

 

 

 

 

 

 

Cannot remember the

 

Contact your service representative.

 

administration menu

 

 

 

 

password.

 

 

 

 

 

 

 

 

Need to abort internal test

Press [STOP]. The current test loop completes, then the test stops.

 

cycle.

 

 

It may take a few minutes to stop the current test loop.

 

 

 

 

 

 