Table 46

 

Error Codes and Recovery Procedures

 

 

 

 

Decimal

Hex

Description

Recovery Method

Error

Error

 

 

 

 

 

 

21

15H

A chassis fan is

Check that the chassis fan cable connection is

 

 

disconnected or

secure.

 

 

faulty.

 

 

 

 

 

22

16H

Chassis interconnect

Check that the chassis interconnect cables are

 

 

cables are

secure.

 

 

disconnected or

 

 

 

faulty.

 

 

 

 

 

23

17H

Front panel cable is

Check that the front panel cable connections are

 

 

disconnected or

secure.

 

 

faulty.

 

 

 

 

 

24

18H

Transport bar code

Power cycle the library.

 

 

reader failed self test.

 

 

 

 

 

25

19H

Library levels

Check for obstructions in the vertical path.

 

 

measured does not

Check that the chassis interconnect cable

 

 

match the number of

 

 

connection is secure.

 

 

levels detected.

 

 

 

 

 

 

 

26

1AH

Upper level fan cable

See Troubleshooting Common Problems on

 

 

failed.

page 140 for troubleshooting procedures.

 

 

 

 

27

1BH

Transport controller

Replace the transport assembly.

 

 

unable to

 

 

 

communicate with

 

 

 

transport.

 

 

 

 

 

28

1CH

Transport controller

Update the library’s firmware (see Upgrading

 

 

needs new firmware.

Firmware on page 176).

 

 

 

 

29

1DH

Failed transport

Update the transport’s firmware (see Upgrading

 

 

firmware download.

Firmware on page 176).

 

 

 

 

50

32H

Test not run, an

If incorrect test number was designated when

 

 

invalid test number

initiating a test over the SCSI interface, select

 

 

was specified.

desired number and then re-initiate the test.

 

 

 

 

212 Library Error Codes