Error Codes and Recovery Procedures

 

 

 

 

Decimal

Hex

Description

Recovery Method

Error

Error

 

 

 

 

 

 

0

00H

Error code not set.

Power cycle the library.

 

 

 

Observe the LEDs on the back of the library

 

 

 

controller card. See Interpreting Library LEDs

 

 

 

on page 130 to understand what the LEDs may

 

 

 

indicate.

 

 

 

 

1-8

01H -

Failed library

01h through 08h are controller tests. These errors

 

08H

controller self test.

are possible only on power-up.

 

 

 

Power cycle the library.

 

 

 

Observe the LEDs on the back of the library

 

 

 

controller card. See Interpreting Library LEDs

 

 

 

on page 130 to understand what the LEDs may

 

 

 

indicate.

 

 

 

If failure persists, the library controller card

 

 

 

may be faulty.

 

 

 

 

9

09H

Failed translate motor

Cannot translate the transport.

 

 

test.

Check for a possible obstruction in the

 

 

 

 

 

 

transport pathway and remove it.

 

 

 

The umbilical cable may be faulty.

 

 

 

If the transport moves a little, but cannot fully

 

 

 

rotate around the assembly, a faulty motor is

 

 

 

indicated.

 

 

 

 

10

0AH

Failed vertical motor

Occurs when trying to sense if the transport

 

 

test.

assembly moves vertically. If the assembly does not

 

 

 

move:

 

 

 

Ensure that the motor leads are connected to

 

 

 

the vertical motor and the vertical lift board.

 

 

 

Check the umbilical cable under the translate

 

 

 

frame.

 

 

 

 