Choosing a Location

 

Choose a location that meets the criteria listed in Table 2. For additional

 

specifications, refer to Technical Specifications on page 181.

Table 2

Location Criteria

 

 

Room temperature

10-35º C (50-95º F)

 

 

Power source

AC power voltage: 100-127 V or 200-240 V

 

Line frequency: 50-60 Hz

 

A dedicated circuit is required.

 

Caution: The AC power cord is the library’s main AC disconnect device and

 

must be easily accessible at all times.

 

 

LAN connection

Locate the library near a LAN connection for connecting the RMC (remote

 

management card).

 

 

 

Library power

2/20 series

Max: 200W

consumption

4/40 series

Max: 375W

 

 

6/60 series

Max: 560W

 

8/80 series

Max: 725W

 

10/100 series

Max: 1,200W

 

 

Air quality

Minimal sources of particulate contamination. Avoid areas near frequently used

 

doors and walkways, stacks of supplies that collect dust, and smoke-filled rooms.

 

Caution: Excessive dust and debris can damage tapes and tape drives.

 

 

 

Humidity

20-80% RH

 

 

 

 

14 Choosing a Location

Chapter 1

Page 16
Image 16
HP 20-Feb manual Choosing a Location, Specifications, refer to Technical Specifications on, Humidity 20-80% RH