Running Library Diagnostic Tests

Main Menu -> Administration -> Run Test

Use the following procedure to run internal tests of library functions. Table 28 on page 156 describes these tests.

1.From Administration, select [More] to display additional administrative options. Select [Run Test].

2.From Run Test, use the [-]or [+] key to view available tests.

3.Select [OK] to select the test.

4.Select the number of times this test will run.

5.Select [Run] to start the test cycle. The test results will display at the conclusion of the test cycle.

 

Note

Select [Stop] to abort a test. The current test cycle completes

 

 

 

before the test stops. Stopping the test may take a few minutes.

 

Table 28

 

 

 

Front Panel Diagnostic Tests

 

 

 

 

 

 

 

 

Test

Description

 

 

 

 

 

 

Check Inventory

Physically scans the entire library to determine

 

 

 

 

which slots and drives contain tapes and reads all

 

 

 

 

bar code labels.

 

 

 

 

 

 

Recalibrate Library

Performs the power-up self-tests. Each test runs one

 

 

 

 

time per test loop. This test recalibrates the

 

 

 

 

mechanics and clears hard errors, but not the hard

 

 

 

 

error log.

 

 

 

 

 

 

Test Lateral Motion

Moves the transport assembly to a random slot. No

 

 

 

 

tape is required.

 

 

 

 

 

 

Test Magazine

Moves a tape from a random slot to an empty,

 

 

Moves

 

random slot, and then returns it to the original

 

 

 

 

location.

 

 

 

 

 

 

156 Diagnostic Support Tools

Chapter 4

Page 158
Image 158
HP 20-Feb manual Running Library Diagnostic Tests, Test Description