Table 46

 

Error Codes and Recovery Procedures

 

 

 

 

 

 

Decimal

Hex

Description

Recovery Method

 

Error

Error

 

 

 

 

 

 

 

 

 

11

0BH

Failed plunge motor

Note the error code qualifier to help determine

 

 

 

test.

appropriate testing.

 

 

 

 

 

 

12

0CH

Transport failed to

Make sure that all tape cartridges are fully

 

 

 

find the translate

seated in their slots.

 

 

 

home position.

 

 

 

 

 

 

 

13

0DH

Transport failed to

Check for a possible obstruction in the

 

 

 

find the vertical home

transport pathway and remove it.

 

 

 

position.

Verify that the vertical path is physically clear.

 

 

 

 

 

 

 

 

Make sure that all tape cartridges are fully

 

 

 

 

seated in their slots. (When manually loaded,

 

 

 

 

cartridges may not have been fully inserted into

 

 

 

 

slots.)

 

 

 

 

 

 

14

0EH

Transport failed to

The plunge motor can be moved. Therefore, the

 

 

 

find the plunge home

motor and umbilical cable are probably not

 

 

 

position.

indicated.

 

 

 

 

Replace the transport assembly.

 

 

 

 

 

 

15

0FH

Has wrong library

Download new firmware (see Upgrading Firmware

 

 

 

family firmware or the

on page 176).

 

 

 

controller is on the

 

 

 

 

wrong level.

 

Appendix

 

 

 

 

18

12H

open.

Close magazine doors.

Failed because

 

 

 

magazine door) is

 

 

 

 

 

 

C

19

13H

Vertical motor cable is

Check that the vertical cable connections are

 

 

 

missing or faulty.

secure.

 

 

 

 

 

 

20

14H

Transport umbilical

Check the transport cable connections or the cable

 

 

 

cable is missing or

that goes from the transport to the library.

 

 

 

faulty.

 

 

 

 

 

 

 

Appendix

Library Error Codes 211

Page 213
Image 213
HP 20-Feb manual 0BH, 0CH, 0DH, 0EH, 0FH