Error Codes and Recovery Procedures

 

 

 

 

Decimal

Hex

Description

Recovery Method

Error

Error

 

 

 

 

 

 

82

52H

Incorrect external

Check the cable configuration (see Connecting and

 

 

SCSI connection.

Powering on the Library on page 32).

 

 

Library connected to

 

 

 

wrong type of SCSI

 

 

 

bus.

 

 

 

 

 

89

59H

Cleaning cartridge

Use a new cleaning cartridge.

 

 

has expired.

 

 

 

 

 

90

5AH

Not a cleaning

Insert a cleaning cartridge.

 

 

cartridge.

 

 

 

 

 

100

64H

Library controller

Power cycle the library.

 

 

unable to

 

 

 

communicate with

 

 

 

drive module.

 

 

 

 

 

101

65H

Drive module unable

Power cycle the library.

 

 

to communicate with

 

 

 

drive.

 

 

 

 

 

102

66H

Drive command

Command timeout on 8051.

 

 

timeout on drive

 

 

 

module controller.

 

 

 

 

 

103

67H

A drive module

Power cycle the library and re-try. Replace the drive

 

 

controller has failed.

module if unsuccessful (see Removing and

 

 

 

Replacing Drive Modules on page 162).

 

 

 

 

104

68H

Failed drive module

Power cycle the library.

 

 

initialization.

 

 

 

 

 

105

69H

Drive module serial

Retry command.

 

 

timeout to drive.

 

 

 

 

 

110

6EH

Library controller

Power cycle the library.

 

 

unable to

 

 

 

communicate with

 

 

 

slave card.

 

 

 

 

 