Appendix E Infrastructure Configuration Example
512 September 2002 HPSS Installation Guide
Release 4.5, Revision 2
<mkhpss> Status ==> DCE is running, continue...
<mkhpss> Perform DCE Register
<hpss_dce_register> Status => Running /opt/hpss/config/hpss_dce_register on host by root
on Tue Aug 28 11:36:22 CDT 2001
<hpss_dce_register> Prompt => Password for cell_admin:
<hpss_dce_register> Prompt => Remove /krb5/hpss.keytabs? (y/n)(y)
<hpss_dce_register> Prompt => Remove /krb5/hpssclient.keytab? (y/n)(y)
<hpss_dce_register> Status => Create the groups, principals and accounts
<hpss_dce_register> Status => Create HPSS Server CDS directories
<hpss_dce_register> Status => Create server, client keytabs files
<hpss_dce_register> Status => Set permisiions on keytab files
<mkhpss> Perform Set up and Check Cell
============================
<hpss_setup_and_check_cell> Status => Found 1 Cell entries:
/.../host_cell.clearlake.ibm.com/krbtgt/host_cell.clearlake.ibm.com
<hpss_setup_and_check_cell> Status => Local Cell is /.../host_cell.clearlake.ibm.com
<hpss_setup_and_check_cell> Status => Extended Registry Attribute, HPSS.CellId , NOT
Defined”
<hpss_setup_and_check_cell> Status => Creating HPSS.CellId ERA
<hpss_setup_and_check_cell> Status => Creating hpss_cross_cell_members ERA
<hpss_setup_and_check_cell> Status => DCE group, hpss_cross_cell_members, Empty
<hpss_setup_and_check_cell> Status => The Local Cell has NO HPSS.CellId Extended Registry
Attribute
<hpss_setup_and_check_cell> Status => Please obtain your HPSS.CellId from IBM
<hpss_setup_and_check_cell> Prompt => Enter Assigned HPSS.CellId:200040
<hpss_setup_and_check_cell> Status => Extended Registry Attribute, HPSS.homedir , NOT
Defined”
<hpss_setup_and_check_cell> Status => Creating HPSS.homedir ERA
<hpss_setup_and_check_cell> Status => Extended Registry Attribute, HPSS.gecos , NOT
Defined”
<hpss_setup_and_check_cell> Status => Creating HPSS.gecos ERA
<hpss_setup_and_check_cell> Status => All HPSS ERAs created (or already existed).
<hpss_setup_and_check_cell> Status => Be sure to populate the HPSS.homedir and hpss.gecos
for all customers.
This application tries to contact every cell in the
“hpss_cross_cell_members” group.
This test will indicate failures in the HPSS configuration
including:
A). The hpss_cross_cell_members group does NOT exist.
B) A krbtgt/... member in the “hpss_cross_cell_members”
group has no CellId ERA
Examine the output to be sure every cell that is expected to be a
Trusted Cross Cell appears in the output.