Lexmark XM3100 manual Miscellaneous Security Settings menu, Understanding the printer menus 162

Models: XM3100

1 350
Download 350 pages 36.24 Kb
Page 162
Image 162

Understanding the printer menus

162

Miscellaneous Security Settings menu

 

Use

To

 

 

 

 

Login Restrictions

Limit the number and time frames of failed login attempts from the printer control

 

Login failures

panel before all users are locked out.

 

Failure time frame

Notes:

 

Lockout time

“Login failures” specifies the number of failed login attempts before users are

 

Panel Login Timeout

 

locked out. Settings range from 1 to 10 attempts is the factory default setting.

 

Remote Login Timeout

 

“Failure time frame” specifies the time frame during which failed login

 

 

 

 

attempts can be made before users are locked out. Settings range from 1 to 60

 

 

minutes. 5 minutes is the factory default setting.

 

 

“Lockout time” specifies how long users are locked out after exceeding the

 

 

login failures limit. Settings range from 1 to 60 minutes. 5 minutes is the

 

 

factory default setting. 1 indicates the printer does not impose a lockout time.

 

 

“Panel Login Timeout” specifies how long the printer remains idle on the

 

 

Home screen before automatically logging the user off. Settings range from 1

 

 

to 900 seconds. 30 seconds is the factory default setting.

 

 

“Remote Login Timeout” specifies how long a remote interface remains idle

 

 

before automatically logging the user off. Settings range from 1 to 120

 

 

seconds. 10 minutes is the factory default setting.

 

 

 

 

Security Reset Jumper

Change the value of the security settings.

 

Access controls=”No Security”

Notes:

 

No Effect

 

Access controls=”No Security” retains all the security information that the user

 

Reset factory security defaults

 

has defined. “No Security" is the factory default setting.

 

 

 

 

“No Effect” means the reset has no effect on the device’s security

 

 

configuration.

 

 

“Reset factory security defaults” deletes all security information that the user

 

 

has defined, and assigns the factory default value to each setting in the

 

 

Miscellaneous Security Settings section of both the panel and the Embedded

 

 

Web Server.

 

 

 

 

LDAP Certificate Verification

Allow the user to request a server certificate.

 

Demand

Notes:

 

Try

 

“Demand” means a server certificate is requested. If a bad certificate is

 

Allow

 

provided or if no certificate is provided, then the session is terminated

 

Never

 

immediately. “Demand” is the factory default setting.

 

 

 

 

“Try” means a server certificate is requested. If no certificate is provided, then

 

 

the session proceeds normally. If a bad certificate is provided, then the session

 

 

is terminated immediately.

 

 

“Allow” means a server certificate is requested. If no certificate is provided,

 

 

then the session proceeds normally. If a bad certificate is provided, then it will

 

 

be ignored, and then the session proceeds normally.

 

 

“Never” means no server certificate is requested.

 

 

 

 

Minimum PIN Length

Limit the digit length of the PIN.

 

1–16

Note: 4 is the is the factory default setting.

 

 

 