4 – Interactive Mode Commands Port Level Info & Operations Menu

S

4.After making changes, refresh the HBA to show these changes by typing 6 (Refresh), and then pressing ENTER. If you do not select this option, your changes will not be visible in SANsurfer iSCSI HBA CLI.

Ping Target

(CLI Option -ping)

To ping a target:

1.On the Port Diagnostic Menu, type the number for the Ping option, and then press ENTER.

SANsurfer iSCSI HBA CLI prompts you as follows:

Enter an IP Address:

2.Type the target IP address, and then press ENTER. SANsurfer iSCSI HBA CLI prompts you as follows:

Enter the number of PING attempts to make:

3.Type a number between 1 and 2147483648 (2^31), and then press ENTER. SANsurfer iSCSI HBA CLI prompts you as follows:

Enter the packet size in bytes for the PING [32]:

4.Type the number you want.

For IPv6 networks, SANsurfer iSCSI HBA CLI prompts you as follows:

Which IPv6 address should be used as the source:

0 = Don't Care

1 = Link Local

2 = Address 0

3 = Address 1

Enter Choice:1 Type the number you want.

Here is an example of a successful ping attempt:

Ping to 10.14.64.153 successful <1 of 2>

Ping to 10.14.64.153 successful <2 of 2>

Press the Enter key to continue.

Here is an example of a ping on an IPv6 network:

Enter an IP Address:fe80::2a0:98ff:fe03:c98e Enter the number of PING attempts to make:1 Enter the packet size in bytes for the PING [32]: Which IPv6 address should be used as the source:

0 = Don't Care

1 = Link Local

2 = Address 0

3 = Address 1

4-30

SN0054621-00 E

Page 64
Image 64
Q-Logic SN0054621-00 E manual Ping Target, To ping a target, Here is an example of a successful ping attempt