136CHAPTER 10: CONFIGURING WAN INTERFACE

Bind the interface to be a pri set

Set the length/attenuation of the transmission cable

Set the line code format

Set line clock

Set frame format

Enable/disable internal loopback/external loopback

1Enter the view for a specified interface

In system view, use the following command to enter the view of a specified CT1/PRI interface.

Table 137 Enter the view of a specified interface

Operation

Command

 

 

Enter the view of CT1/PRI interface

controller t1 number

 

 

2Bind the interface to be channel sets

Perform the following configurations in CT1/PRI interface view.

Table 138 Bind the interface to be channel sets

Operation

Command

 

 

Bind the timeslots of CT1/PRI interface to a

channel-set set-number

channel set

timeslot-list range [ speed { 56

 

64 } ]

 

 

Remove binding timeslots to form channel

undo channel-set set-number

sets

 

 

 

The timeslots can be bind to form up to 24 on a CT1/PRI interface.

The CE1/PRI interface can be bound to be channel sets only when it is enabled to operate in CE1/PRI mode through the using ce1 command.

Only one timeslot binding mode is supported on one CT1/PRI interface at one time, that is, the interface can only be bound into either channel sets or a pri set in that period.

After binding the interface to be channel sets, the system will automatically create a Serial interface numbered serial number:set-number. This interface has the same logic feature as that of a synchronous serial interface, and can be treated as a synchronous serial interface for further configurations.

Perform the following configuration in all views.

Table 139 Enter the synchronous serial interface view

Operation

Command

 

 

Enter the synchronous serial interface view

interface serial

 

number:set-number

 

 

The following is to be set:

Operating parameters of data link layer protocol, such as PPP, Frame Relay, LAPB or X.25.

IP address

The operating parameters of the standby center need to be set when the interface serves as the main interface or standby interface of the standby center.

Page 140
Image 140
3Com 10014299 manual Operation Command Enter the view of CT1/PRI interface, Controller t1 number, Timeslot-list range speed