Typical Bridge Configuration 311

Transparent Bridging for

I. Networking Requirements

Asynchronous Dial-in

Configure transparent bridging for asynchronous dial-in standby on two routers.

Standby

Thereby, transparent bridging can be implemented by enabling asynchronous

 

 

dial-in in case that the serial interfaces through which the routers are directly

 

connected are failed.

II. Networking Diagram

Please refer to Figure 113.

III.Configuration Procedure 1 Configure Router A

[Router]bridge enable

[Router]bridge stp timer forward-delay 4

[Router]bridge 1 stp ieee

[Router]dialer-rule 1 bridge permit

[Router]interface serial 1 [Router-Serial1]link-protocol ppp

[Router-Serial1]physical-mode async

[Router-Serial1]modem

[Router-Serial1]async mode protocol

[Router-Serial1]dialer enable-legacy

[Router-Serial1]dialer-group 1

[Router-Serial1]dialer route bridge broadcast 660074

[Router-Serial1]bridge-set 1

[Router-Serial1]interface serial 0

[Router-Serial0]standby interface Serial 1

[Router-Serial0]bridge-set 1

[Router-Serial0]interface ethernet0 [Router-Ethernet0]bridge-set 1

[Router-Ethernet0]bridge-set 1 stp disable

2Configure Router B

[Router]bridge enable

[Router]bridge stp timer forward-delay 4

[Router]bridge 1 stp ieee

[Router]dialer-rule 1 bridge permit

[Router]interface serial 1 [Router-Serial1]link-protocol ppp

[Router-Serial1]physical-mode async

[Router-Serial1]modem

[Router-Serial1]async mode protocol

[Router-Serial1]dialer enable-legacy

[Router-Serial1]dialer-group 1

[Router-Serial1]dialer number

[Router-Serial1]bridge-set 1

[Router-Serial1]interface serial 0

[Router-Serial0]bridge-set 1

[Router-Serial0]interface ethernet0 [Router-Ethernet0]bridge-set 1

[Router-Ethernet0]bridge-set 1 stp disable

Page 315
Image 315
3Com 10014299 manual Asynchronous Dial-in, Standby, Connected are failed, Please refer to Figure, Transparent Bridging for