Configure Frame Relay 249

 

 

Restore the default value of the LMI event

undo fr lmi n393dce

counter

 

 

 

Set the link integrity polling timer at the user side

fr lmi t391dte [ t391-value]

(T391 DTE)

 

 

 

Restore the default value of the link integrity

undo fr lmi t391dte

polling timer at the user side

 

 

 

Set the polling timer at the network side (T392

fr lmi t392dce [ t392-value]

DCE)

 

 

 

Restore the default value of the polling timer at

undo fr lmi t392dce

the network side

 

 

 

The following table describes the value ranges and default values of related parameters of the Frame Relay LMI protocol

Table 278 Descriptions of related parameters of Frame Relay LMI protocol

Operation

 

 

 

mode

Parameter description

Value range

Default value

 

 

 

 

 

DTE

Link integrity polling timer (T391)

5 to 30 seconds

10 seconds

 

 

When T391 = 0, it indicates that the

 

 

 

 

LMI protocol is disabled.

 

 

 

 

 

 

 

 

 

Counter on the PVC full status

1 to 255 times

6 times

 

 

message polling requests (N391)

 

 

 

 

 

 

 

 

 

Error threshold counter at the user

1 to 10 times

3 times

 

 

side (N392)

 

 

 

 

 

 

 

 

 

Event counter at the user side (N393)

1 to 10 times

4 times

 

 

 

 

 

DCE

Polling authentication timer at the

5 to 30 seconds

15 seconds

 

 

network side (T392)

 

 

 

 

 

 

 

 

 

Error threshold counter at the

1 to 10 times

3 times

 

 

network side (N392)

 

 

 

 

 

 

 

 

 

Event counter at the network side

1 to 10 times

4 times

 

 

(N393)

 

 

 

 

 

 

 

In which, the related parameters at the DTE side include:

T391DTE: The interval of the link integrity polling for the equipment at the DTE side

N391DTE: DTE equipment will send a status enquiry message at a certain interval (which is determined by T391). The status enquiry messages are divided into two types: link integrity authentication messages and link status enquiry messages. The parameter N391DTE is used to define the sending ratio of these two types of messages. That is:

Number of link integrity authentication messages: Number of link status enquiry

messages = N391-1: 1

N392DTE: The threshold for the errors that can occur in the total number of observed events at the DTE side.

N393DTE: The total number of observed events at the DTE side.

DTE equipment will send a status enquiry message at a certain interval (which is determined by T391) to inquire the link status. Upon receiving that message, the DCE equipment sends the status response message promptly. If the DTE equipment does not receive the response in the specified time, the error will be recorded. If the number of errors exceeds the threshold, the DTE equipment will regard the physical path and all the virtual circuits as unusable. The parameters N392 and N393 together define the “error threshold”. That is, if the number of errors in the N393 status enquiry messages sent by the DTE equipment reaches