CT1/PRI Interface 137

The rules for address translation or packet filtering need to be set if the firewall is to be set up on the interface.

For more details, refer to the related sections of this manual.

3Bind an interface to be a pri set

Perform the following configurations in CT1/PRI interface view.

Table 140 Bind the interface to be a pri set

Operation

Command

 

 

Bind the timeslots of CT1/PRI interface to be a

pri-set [ timeslot-list range

pri set

]

 

 

Remove binding timeslots to be a pri set

undo pri-set

 

 

Timeslots on a CT1/PRI interface can be bound to be only one pri set.

When binding an interface to be a pri set, timeslot 24 is used as the D channel and the other timeslots are used as B channels. If no timeslots are specified to be bound, all the timeslots will be bound to form an interface similar to an ISDN PRI interface of 23B+D. If only timeslot 24 on the CT1/PRI interface is bound, the binding activity will fail.

Only one timeslot binding mode is supported on one CT1/PRI interface at one time, that is, the interface can only be bound into either channel sets or a pri set.

After the interface is bound to be a pri set, the system will automatically create a Serial interface numbered serial number:23. This interface is logically equivalent to an ISDN PRI interface, and hence you can further configure it.

Perform the following configuration in all views.

Table 141 Enter the ISDN interface view

Operation

Command

 

 

Enter the ISDN interface view

interface serial number:23

 

 

The following is to be set:

BDR operating parameters

Encapsulate the data link layer protocol PPP, its authentication parameters and etc.

IP address

The operating parameters of the standby center need to be set when the interface serves as the main interface or standby interface of the standby center.

Configure the firewall if necessary.

For more details, refer to the related sections of this manual.

4Set the length/attenuation of the transmission cable

When the CT1/PRI interface connects the transmission cables of different lengths, to ensure the quality of the signal to be received by the receiving end, the attenuation and waveform of signal should match the transmission cables.

Perform the following configurations in CT1/PRI interface view.

Table 142 Set the length/attenuation of the transmission cable of CT1/PRI interface

Operation

Command

Page 141
Image 141
3Com 10014299 manual Bind the interface to be a pri set, Interface serial number23