394CHAPTER 25: CONFIGURING DLSW

By default, the modulo value of SDLC is 8.

dConfigure Maximum Receivable Frame Length N1 of SDLC

Maximum frame length of SDLC refers to byte number of maximum transmissible and receivable message, not including parity bit and stop bit.

Please process the following configurations in the synchronous interface view.

Table 457 Configure maximum receivable frame length of SDLC

Operation

Command

 

 

 

Configure Maximum Receivable Frame Length of SDLC

sdlc

max-pdu n

 

 

 

Restore the default value of maximum receivable frame

undo

sdlc max-pdu

length of SDLC

 

 

 

 

 

By default, the maximum receivable frame length of SDLC is 265 bytes.

Generally, the length is 265 for some PU2.0 equipment and 521 for IBM AS/400. We often need to configure our equipment to be of the same values as the connected SDLC equipment.

eConfigure Retransmission Number N2 of SDLC

The retransmission number N2 of SDLC refers to the retransmission number before receiving no acknowledgement packet sent by the other part.

Please process the following configurations in the synchronous interface view.

Table 458 Configure retransmission number of SDLC

Operation

Command

 

 

 

Configure retransmission number of SDLC

sdlc

max-transmission

 

retries

 

 

 

Restore the default value of the retransmission

undo

sdlc max-transmission

number of SDLC

 

 

 

 

 

By default, the retransmission number of SDLC is 20.

fConfigure Poll Time Interval of SDLC

Poll time interval of SDLC refers to wait time interval between two SDLC nodes polled by SDLC primary station.

Please process the following configurations in the synchronous interface view.

Table 459 Configure poll time interval of SDLC

Operation

Command

 

 

 

Configure poll time interval of SDLC

sdlc

timer poll mseconds

 

 

 

Restore the default value of poll time interval of SDLC

undo

sdlc timer poll

 

 

 

By default, the poll time interval of SDLC is 100 ms.

gConfigure SAP address for transforming SDLC to LLC2

When transforming SDLC message to LLC2 message, it needs both SAP and MAC addresses. This command is used to specify SAP address used when transforming LLC2 for a SDLC byte.

Generally, the SAP address used by SNA protocol is 0x04, 0x08 or 0x0C. Please process the following configurations in the synchronous interface view.

Page 398
Image 398
3Com 10014299 manual Configure maximum receivable frame length of Sdlc, Configure retransmission number of Sdlc