Configuration of DLSw 393

Table 452 Configure REJ status time of LLC2

 

 

 

 

Operation

Command

 

 

 

Configure REJ status time of LLC2

llc2

timer reject mseconds

 

 

 

Restore the default value of REJ status time of LLC2

undo

llc2 timer reject

 

 

 

By default, REJ status time of LLC2 is 500 ms.

jConfigure Queue Length of Sending Message of LLC2

Please process the following configurations in the Ethernet interface view.

Table 453 Configure queue length of sending message of LLC2

Operation

Command

 

 

 

Configure queue length of sending message of LLC2

llc2

max-send-queue length

 

 

 

Restore the default value of queue length of sending

undo

llc2 max-send-queue

message of LLC2

 

 

 

 

 

By default, the queue length of sending message of LLC2 is 50.

18Configure Other Parameters of SDLC

a Configure Queue Length of Sending Message of SDLC

Please process the following configurations in the synchronous interface view.

Table 454 Configure queue length of sending message of SDLC

Operation

Command

 

 

 

Configure queue length of sending message of SDLC

sdlc

max-send-queue length

 

 

 

Restore the default value of queue length of sending

undo

sdlc max-send-queue

message of SDLC

 

 

 

 

 

By default, the queue length of sending message of SDLC is 50.

bConfigure SDLC Local Acknowledgement Window

SDLC Local Acknowledgement Window adopts the window mechanism when sending packets, while not requiring the timely reply for each packet. SDLC Local Acknowledgement Window can wait for the replies from the peer at the same time after the whole window has been sent.

Please process the following configurations in the synchronous interface view.

Table 455 Configure SDLC local acknowledgement window

Operation

Command

 

 

Configure the length of SDLC local acknowledgement

sdlc window length

window

 

 

 

Restore the default length value of SDLC local

undo sdlc window

acknowledgement window

 

 

 

By default, the length of SDLC local acknowledgement window is 7.

cConfigure Modulo Value of SDLC

SDLC uses modulo mode to number the information message like X25 protocol. The modulo value is 8 or 128. SDLC generally uses modulo 8.

Please process the following configurations in the synchronous interface view.

Table 456 Configure modulo value of SDLC

Operation

Command

 

 

Configure Modulo Value of SDLC

sdlc modulo n

 

 

Restore the default value of SDLC modulo value

undo sdlc modulo

 

 

Page 397