388CHAPTER 25: CONFIGURING DLSW

partner shall be the MAC address of the remote end SNA equipment (physical addresses of such equipment as Ethernet and Token-Ring) or next-hop MAC address composed of SDLC.

Please process the following configurations in the synchronous interface view.

Table 436 Configure SDLC peer entity

Operation

Command

 

 

Configure SDLC peer entity

sdlc mac-map remote mac-addr

 

sdlc-addr

 

 

Delete SDLC peer entity

undo sdlc mac-map remote mac-addr

 

sdlc-addr

 

 

By default, synchronous interface is not configured with SDLC peer entity.

Note the differences between the word digital order of Token-Ring and Ethernet. When configuring Token-Ring, you can configure it according to the address labeled on the equipment directly. When configuring Ethernet, you should reverse every Byte. For example, as to Ethernet MAC address, it should be configured to 0007.3fc0.5a12 if the mark is 00e0.fc03.a548. Thereinto, the first byte "00" of 00e0 is reversed as "00", the binary form of the second byte "e0" is 11100000, after reversed, it is 00000111, that is "07" in hexadecimal form. Computed in this way, "3fc0" is reversed form of "fc03", and "5a12" is the reversed form of "a548".

10Configure XID of SDLC

XID is used to identify an identity of equipment in SNA. Generally, there are two kinds of equipment - PU2.0 and PU2.1.PU2.1 equipment is configured with XID and can show their identities each other by exchanging XID. PU2.0 equipment does not exchange XID and it does not include XID. Thus PU2.1 equipment does not need this command, but you have to specify a XID for PU2.0 equipment.

Please process the following configurations in the synchronous interface view.

Table 437 Configure XID of SDLC

Operation

Command

 

 

Configure XID of SDLC

sdlc xid sdlc-address

 

xid-number

 

 

Delete XID of SDLC

undo sdlc xid sdlc-address

 

 

By default, synchronous interface is not configured with XID of SDLC.

11Configure to Add the Sync Interface to Bridge Set

To allow the synchronous interface encapsulated with SDLC to participate in DLSw forwarding, you need to use this command to add SDLC interface to a Bridge set. The Bridge set on Ethernet interface takes part in the local forwarding, but the Bridge set configured in the SDLC only takes part in DLSw forwarding, that is, all of the data on it will be forwarded to TCP channels.

Please process the following configurations in the synchronous interface view.

Table 438 Add synchronous Interface to Bridge set

Operation

Command

 

 

Add synchronous interface to Bridge set

bridge-set

 

bridge-set-number

 

 

Delete the configuration of adding synchronous

undo bridge-set

interface to Bridge set

bridge-set-number

 

 