DCC Configuration Examples 731

DCC Configuration Examples

DCC Applications in Common Use

RouterA can call RouterB and RouterC via multiple interfaces. Likewise, RouterB and RouterC can respectively call RouterA. However, RouterB and RouterC cannot call each other.

As shown in Figure 233, when circular DCC is used, the addresses of RouterA, RouterB and RouterC are on the same segment. In this case, 100.1.1.1, 100.1.1.2, and 100.1.1.3 are the addresses respectively for RouterA, RouterB and RouterC. When resource-shared DCC are used, the addresses of RouterA and RouterB are on the same segment, so are the addresses of RouterA and RouterC. The addresses of the interfaces Dialer0 and Dialer1 on RouterA are respectively

100.1.1.1and 122.1.1.1. The address of the Dialer0 on RouterB is 100.1.1.2, and that of the Dialer0 on RouterC is 122.1.1.2.

Figure 233 Network of a DCC application in common use

 

 

 

Serial0

Serial0

8810048

8810052

 

Modem

Modem

Router B

 

 

 

PSTN

 

 

 

 

Serial0

Router A

 

8810049

8810063

Serial1

Modem

 

Modem

Connecting via serial interfaces across PSTN

 

Bri0

8810152

 

 

 

 

 

 

8810148

NT1

 

NT1

ISDN

 

 

8810163

 

Router D

 

NT1

 

 

 

Connecting via ISDN BRI or PRI interfaces across ISDN

 

 

Router C

Bri0

Router E

Bri0

Router F

Solution 1

Establish a connection via the serial interface by using Circular DCC, configure the DCC parameters on the dialer interface for RouterA with the help of a dialer circular group, and directly configure the DCC parameters on the physical interfaces on RouterB and RouterC.

1Configure RouterA:

[Router] dialer-rule 1 ip permit

[Router] interface dialer 0

[Router-Dialer0]ip address 100.1.1.1 255.255.255.0

[Router-Dialer0]dialer enable-circular

[Router-Dialer0] dialer-group 1

[Router-Dialer0]dialer route ip 100.1.1.2 8810052

[Router-Dialer0]dialer route ip 100.1.1.3 8810063

[Router-Dialer0]interface serial 0

[Router-Serial0]physical-mode async

[Router-Serial0] modem

Page 735
Image 735