Troubleshooting DCC 747

Use the DCC Debugging

Information to Locate

Problems

Enabling DCC debugging

Execute the following commands in system view for displaying the DCC debugging information:

[Router] debugging dialer event

[Router] debugging dialer packet

[Router] info-center enable

Output debugging information for the interconnection failure between DCC and the remote end and diagnosis

In this section, the debugging information that may be output when DCC cannot reach the remote end will be displayed and explained. The user can solve the problems with the solutions recommended in this section.

Table 774 DCC Fault Messages

Message

Fault

 

 

DCC: Receive CALL_DISC_IND

The debugging information is probably output

 

because:

 

The physical connection between the local and

 

remote ends is down, phone cable is not securely

 

connected to the router, or the quality of phone

 

line is not good.

 

PPP authentication is not correctly configured, so

 

the PPP authentication is failed.

 

Remote DCC authentication is failed, because

 

name in the commands dialer user and dialer

 

route configured for DCC is inconsistent with

 

name configured for PPP authentication, and the

 

dialer route at the remote end does not contain

 

the local network address.

 

The remote end disconnects the connection

 

because the remote DCC idle-timeout timer has

 

timed out.

 

Solution:

 

If PPP configuration is incorrect or name

 

configurations are inconsistent, implement the

 

configuration as shown in the above example.

 

If it is the problem of the network address, apply

 

the following measures in the configuration of the

 

remote end: Add the dialer route corresponding to

 

the network address of the local router on the

 

remote router. Alternatively, remove all the dialer

 

routes configured at the remote end, and use the

 

dial number.

 

 

DCC: link negotiation Down on

The link is probably disconnected because PPP

interface ***

negotiation is failed due to a wrong PPP

 

configuration. To solve the problem, refer to the

 

previous example to make the configuration.

 

 

DCC: NAME authentication ERROR,

The debugging information is probably outputted

failed

because name configured in the commands dialer

 

user and dialer route is inconsistent with that

 

configured in PPP authentication. The connection is

 

disconnected since the local DCC authentication

 

has been failed. To solve the problem, refer to the

 

previous example to make the configuration.

 

 

Page 751
Image 751
3Com 10014299 manual DCC Fault Messages, Message Fault