Configuration of DLSw 389

12Configure to Stop Running DLSw

Please carry out the following configuration under overall view.

Table 439 Configure to stop running DLSw

Operation

Command

 

 

 

Enable running DLSw

dlsw

enable

 

 

 

Stop running DLSw

undo

dlsw enable

 

 

 

By default, the system does not run DLSw protocol.

After using this command, the system will release all the dynamic resources but reserve the existing configuration.

13Configure Baud Rate of Sync Interface

All of the above commands are some of basic commands for configuring DLSw. SNA equipment have diversified sorts and quite differences in the factual environment. The following commands are some frequently used adjustment parameters used to make the different equipment compatible.

Please process the following configurations in the synchronous interface view.

Table 440 Configure baud rate of synchronous Interface

Operation

Command

 

 

 

 

Configure baud rate of synchronous interface

baudrate

baudrate

 

 

 

By default, the baud rate of the serial interface on SNA equipment is 9600bps.

14 Configure Encoding Mode of Sync Interface

There are two kinds of encoding modes including NRZI and NRZ on the synchronous serial interface. The routers in our company generally use NRZ encoding mode, but the encoding mode of the serial ports in some SNA equipment uses NRZI. So you need to change the encoding of routers according to the encoding mode used by the connected equipment.

This command is used to change the encoding mode of synchronous serial interface.

Please process the following configurations in the synchronous interface view. Table 441 Configure encoding mode of synchronous Interface

Operation

Command

 

 

 

Configure NRZI encoding mode of synchronous interface

code

nrzi

 

 

 

Delete NRZI encoding mode of synchronous interface

undo

code nrzi

 

 

 

By default, the synchronous interface uses encoding mode NRZ.

15 Configure Idle Time Encoding Mode of Sync Interface

The SDLC serial ports of the 3Com Router series of routers is identified with “7E” during the idle time, but all of the serial ports on some SDLC equipment use high level working status “1” during the idle time. To improve the compatibility with the equipment, you need to change the idle time encoding mode of the routers.

Please process the following configurations in the synchronous interface view.

Page 393
Image 393
3Com 10014299 manual Configure to stop running DLSw, Configure baud rate of synchronous Interface, Baudrate