206CHAPTER 16: CONFIGURING LAPB AND X.25

Table 244 Configure/Cancel the attributes related to the address code block in the call packet or call accept packet

Operation

Command

 

 

Not carrying the called DTE address information when a

x25 ignore

call is originated

called-address (by

Default: carry

default)

 

 

Cancel not carrying the called DTE address information

undo x25 ignore

when a call is originated

called-address

 

 

Not carrying the calling DTE address information when a

x25 ignore

call is originated

calling-address (by

Default: carry

default)

 

 

Cancel not carrying of the calling DTE address

undo x25 ignore

information in a call

calling-address

 

 

Not carrying the called DTE address information when

x25 response

the originated call is accepted

called-address

Default: not carry

 

 

 

Cancel not carrying of the called DTE address

undo x25 response

information when the originated call is accepted

called-address (by

 

default)

 

 

Not carrying the calling DTE address information when

x25 response

the originated call is accepted

calling-address

Default: not carry

 

 

 

Cancel not carrying the calling DTE address information

undo x25 response

when the originated call is accepted

calling-address (by

 

default)

 

 

Check the address code block after the response of the

x25

call is received

check-response-address

Default: check

(by default)

 

 

Cancel check the address code block after the response

undo x25

of the call is received

check-response-address

 

 

4Configure default upper layer protocol

X.25 call request packet includes a CUD field (Call User Data), which shows the upper layer protocol type X.25 protocol carries. When receiving X.25 calls, the router will check packet CUD field; when receiving calls carrying the CUD fields that cannot be identified, it will reject them. But an upper layer protocol can be specified as the default protocol borne on the X.25 of the 3Com Router series.

When the X.25 of the 3Com Router series receives a call with an unrecognizable CUD, it will treat it as the default upper layer protocol specified by user.

In the interface view, perform the following task to set/cancel the default upper layer protocol borne on X.25.

Table 245 Set/Cancel the default upper layer protocol borne on X.25

Operation

Command

 

 

Specify the default upper layer protocol borne on

x25 default-protocol [ ip

X.25

ipx ]

Default: IP

 

 

 

Cancel the specifying of the default upper layer

undo x25 default-protocol

protocol borne on X.25

[ ip ipx ]

 

 

By default, the upper protocol carried by X.25 is IP protocol.

Page 210
Image 210
3Com 10014299 manual Set/Cancel the default upper layer protocol borne on