125
Triggering Examples
Cross-Arming Trigger Examples
To trigger timing analysis of a count-down on a set of data lines
Your target system may include various state machines that are started
by system events such as interrupt processing or I/O activity. The state
analyzer is ideal for recognizing the system events; the timing analyzer
is ideal for examining the step-by-step operation of the state machines.
1Set up a timing analyzer and a state analyzer.
2Go to the state analyzers Trigger menu.
3Set the timing analyzer to be run from the state analyzer.
4Set the state analyzer to trigger on the label and term that
identify the start of the count-down routine.
5Go to the timing analyzers Trigger Menu.
6Set the timing analyzer to trigger on any state and store any
state.