519
Retrieving and Restoring Data Using the LAN
Retrieving and Restoring Data Using the LAN
To copy configurations from setup.raw

1Set up the configuration.

You can do this from the XWindow interface or from the front panel.

2Access the logic analyzers file system.

Refer to the chapter "Accessing the Logic Analyzer File System".

3Copy the setup.raw file from the appropriate directory.

For system configurations, the appropriate directory is \system . For
analyzer configurations, the appropriate directory is \slot_a . For
oscilloscope configurations, the appropriate directory is \slot_b .
Raw configuration files are binary format files that can be transferred
to your computer and then reloaded into the logic analyzer later. Raw
configuration files are not transferable between logic analyzer models.
The setup.raw file is overwritten whenever you change the
configuration.

Dynamic Configuration Files

Configuration files are dynamic files. When you look at the logic
analyzer file system, dynamic files show a file size of 1 or 0. 0 means
there isnt anything available and 1 means there is. When you request
the dynamic file, the logic analyzer creates it. While the analyzer is
creating the file, it will not respond to other requests. Because the
analyzer does not know the file size until it is created, some NFS
systems have trouble copying dynamic files. If the cp command does
not appear to work, try using dd.