316
Logic Analyzer Reference
The Analyzer Trigger Menu
State trigger function library
The following list contains all the functions in the library of state
trigger functions. They are listed in the same order as they appear
onscreen.
User Mode Use r level - custom combinations, loops
The User level is a user-definable level. This level offers low-level
configuration and uses one internal sequence level.
Basic Functions 1. Find event "n" times
This function becomes true when it sees a designated pattern
occurring a designated number of times consecutively or
nonconsecutively. It uses one internal sequence level.
2. Find event "n" consecutive times
This function becomes true when it sees a designated pattern
occurring a designated number of consecutive times. It uses one
internal sequence level.
3. Find event 2 immediately after event 1
This function becomes true when the first designated pattern is seen
immediately followed by a second designated pattern. It uses two
internal sequence levels.
4. Find anystate "n" times
This function becomes true when the first state it sees occurs "n"
number of times. It uses one internal sequence level.