90
Using the Trigger Menu
Managing Memory
To selectively store branch conditions (state only)
Besides setting up your trigger levels to store anystate, no state, or
some subset of states, you can also choose whether or not to store
branch conditions. Branch conditions are always stored by default, and
can make tracing the analyzers path through a complicated trigger
easier. If you really need the extra memory, however, it is possible to
not store the branch conditions.
You cannot set the analyzer to store only some branches in a trigger
sequence specification.
1In the Analyzer Trigger menu, select Acquisition Control.
The Acquisition Control menu pops up. If the acquisition mode is set to
Automatic, the menu contains a single field and an explanation. If
Acquisition has been customized, it has 3 fields and a picture showing
where the trigger is currently placed in memory.
2If the mode is Automatic, select the field and toggle it to Manual.
The menu now shows three fields and a picture.
3Select the Branches Taken Stored field.
It toggles to Branches Taken Not Stored.
4Select Done.