Agilent Technologies E4406A VSA SENSe:ACP:SWEep:BANDwidth|BWIDth:RESolution:AUTO, OFF|ON|0|1

Models: E4406A VSA

1 406
Download 406 pages 63.49 Kb
Page 314
Image 314
[:SENSe]:ACP:SWEep:BANDwidthBWIDth[:RESolution]:AUTO

Language Reference

SENSe Subsystem

Adjacent Channel Power—Sweep Mode Resolution BW Control

[:SENSe]:ACP:SWEep:BANDwidthBWIDth[:RESolution]:AUTO

OFFON01

[:SENSe]:ACP:SWEep:BANDwidthBWIDth[:RESolution]:AUTO?

Sets the resolution bandwidth to automatic, when using the spectrum analyzer type sweep mode. See [:SENSe]:ACP:SWEep:TYPE.

Factory Preset

 

and *RST:

ON

Remarks:

You must be in the cdmaOne cdma2000, W-CDMA

 

(3GPP), or W-CDMA (Trial & Arib) mode to use this

 

command. Use INSTrument:SELect to set the mode.

Adjacent Channel Power—Sweep Mode Detection

[:SENSe]:ACP:SWEep:DETector[:FUNCtion] AAVeragePOSitive

[:SENSe]:ACP:SWEep:DETector[:FUNCtion]?

Selects the detector type when using the sweep mode. See [:SENSe]:ACP:SWEep:TYPE.

Absolute average (AAVerage) - the absolute average power in each frequency is measured across the spectrum

Positive - the positive peak power in each frequency is measured across the spectrum

Factory Preset

 

and *RST:

POSitive

Remarks:

You must be in the cdma2000, W-CDMA (3GPP), or

 

W-CDMA (Trial & Arib) mode to use this command.

 

Use INSTrument:SELect to set the mode.

Adjacent Channel Power—Sweep Time

[:SENSe]:ACP:SWEep:TIME <seconds>

[:SENSe]:ACP:SWEep:TIME?

Selects a specific sweep time used to measure the reference (carrier) channel. If you increase the sweep time, you increase the length of the time data captured and the number of points measured. You might need to specify a specific sweep speed to accommodate a specific condition in your transmitter. For example, you may have a burst signal and need to measure an exact portion of the burst.

314

Chapter 5

Page 314
Image 314
Agilent Technologies E4406A VSA manual SENSe:ACP:SWEep:BANDwidth|BWIDth:RESolution:AUTO, OFF|ON|0|1, SENSe:ACP:SWEep:TIME?