Questionable Temperature Positive Transition

Language Reference

STATus Subsystem

Questionable Temperature Positive Transition

:STATus:QUEStionable:TEMPerature:PTRansition <number>

:STATus:QUEStionable:TEMPerature:PTRansition?

This command determines what bits in the Questionable Temperature Condition register will set the corresponding bit in the Questionable Temperature Event register when the condition register bit has a positive transition (0 to 1). The variable <number> is the sum of the decimal values of the bits that you want to enable.

Key Type:

There is no equivalent front panel key.

Factory Preset

 

and *RST:

32767 (all 1’s)

Range:

0 to 32767