AMD | P R E L I M I N A R Y |
|
|
edge baud counter. This information should be used to appropri- ately program the Baud Detect Upper Limit register.
The resolution of the value in this register is the period of the CLKIN signal when the CLKGT20 bit of MIR9 is set to 0 or twice the period of the CLKIN signal when the CLKGT20 bit of MIR9 is set to 1. With CLKIN = 20 MHz and CLKGT20=0, a value of 14h (=20 decimal) represents the nominal like transition separation value for a 1Mbit/s network data rate.
TCR19: Baud Detect Accept Count for Carrier Sense
This register is the Baud Detect Accept Count for Carrier Sense register. When the number of positive baud de- tect test results in the baud detection circuit reaches the value in this register, then the total number of tests taken
to that point will be considered adequate to make a valid determination of positive carrier sense. The number of positive baud detect test results is reset to 0 each time that the antenna selection is changed.
CONFIGURATION REGISTER INDEX: | 13h | ||
Bit | Name | Reset Value | Description |
|
|
|
|
Reserved | – | Reserved. Must be written as a 0. Reads of this bit produce | |
|
|
| undefined data. |
BDCS[5:0] | 00h | Baud Detect accept count for Carrier Sense. When the number of |
positive baud detect test results in the baud detection circuit reaches the value in this register, then the total number of tests taken to that point will be considered adequate to make a valid de- termination of positive carrier sense. The number of positive baud detect test results is reset to 0 each time that the antenna selection is changed.
TCR20: Baud Detect Accept Count for Stop Diversity
This register is the Baud Detect Accept Count for Stop Diversity register. When the number of positive baud de- tect test results in the baud detection circuit reaches the value in this register, then the total number of tests taken
to that point will be considered adequate to make a valid determination of satisfactory antenna selection. The number of positive baud detect test results is reset to 0 each time that the antenna selection is changed.
CONFIGURATION REGISTER INDEX: | 14h | ||
Bit | Name | Reset Value | Description |
|
|
|
|
Reserved | – | Reserved. Must be written as a 0. Reads of this bit produce unde- | |
|
|
| fined data. |
BDSD[5:0] | 00h | Baud Detect accept count for Stop Diversity. When the number of |
positive baud detect test results in the baud detection circuit reaches the value in this register, then the total number of tests taken to that point will be considered adequate to make a valid de- termination of satisfactory antenna selection. The number of posi- tive baud detect test results is reset to 0 each time that the antenna selection is changed.
TCR21: Baud Detect Ratio
This register is the Baud Detect Ratio register. This reg- ister is used to set the ratio of good to bad baud detec- tions which will be used as the minimum ratio to determine that a valid signal is present on the medium.
The value in this register is treated as a radix 2 positive real number with two decimal places. The lowest practi- cal value possible is 0.25 (=00.01) and the highest prac- tical value is 3.75 (=11.11).
116 | Am79C930 |