The 60x Bus
MPC8260 PowerQUICC II Family Reference Manual, Rev. 2
Freescale Semiconductor 8-9
Figure 8-5. Address Pipelining
8.4.3 Address Transfer Attribute Signals
During the address transfer, the address is placed on the address signals, A[0–31]. The bus master provides
other signals that characterize the address transfer—transfer type (TT[0–4]), transfer code (TC[0–2]),
transfer size (TSIZ[0–3]), and transfer burst (TBST) signals. These signals are discussed in the following
sections.

8.4.3.1 Transfer Type Signal (TT[0–4]) Encoding

The transfer type signals define the nature of the transfer requested. They indicate whether the operation
is an address-only transaction or whether both address and data are to be transferred. Tab le 8-2 describes
the PowerQUICC II’s action as master, slave, and snooper.
CLKOUT
ADDR + ATTR
TS
AACK
DBG
TA
Address
Data Tenure
Tenure Address 1
Data 1
Address 2
Data 2