Baud-Rate Generators (BRGs)
MPC8260 PowerQUICC II Family Reference Manual, Rev. 2
17-6 Freescale Semiconductor
For example, to get a rate of 64 kbps, the system clock can be 24.96 MHz, BRGCx[DIV16]= 0, and
BRGCx[CD] = 389.
BRGCx[EXTC]
BRGCx[DIV16]()BRGCx[CD] + 1()
------------------------------------------------------------------------------------------------
=