GFK-2489 Chapter 5 Sample Configurations 5-19
5
Mixed-Mode Application Example
In this configuration, the Host PC can use both TCP and serial-to-serial data paths to reach
the endpoint devices. This may be helpful when a mixed collection of endpoint devices is
present, where some endpoint devices operate via Ethernet while others are polled via a
serial port..
Operation and Data Flow
Communicate with endpoint devices A and B by sending and receiving data from the AP
COM2 port.
Communicate with endpoint devices C and D by Telneting to the IP address of each
endpoint device.
TS Wireless Menu Item Setting
radio Location
AP (COM2) Port Status Enabled
Mode Serial-to-Serial
Remote UnitID Broadcast
Remote COM Port COM2
Baud Rate 19200
Byte Format 8N1
Buffer size 256 Bytes
Inter-Packet Delay 4 Characters
Remote radios 1 and 2 Mode Data
(COM2) Baud Rate 19200
Data Format 8N1
Buffer Size 256
DelayChars 4
Remote radios 3 and 4 Mode On
(ETH)