GE GFK-2489 user manual Physical Interface

Models: GFK-2489

1 184
Download 184 pages 20.15 Kb
Page 174
Image 174

8

Physical Interface

Ethernet Port:

10BaseT, RJ-45, 10 Mbps

Serial Port:

RS-232/V.24, RJ-45, DCE

 

1,200-115,200 bps asynchronous

Antenna Connector:

TNC female

LED Indicators:

LAN (AP), ETH (Remote), COM1, COM2, PWR, LINK

Data Characteristics

 

Protocols Supported:

IEEE (Institute of Electrical and Electronic Engineers) 802.3 (single device at

 

Remote) (Ethernet)

 

IP or Ethernet (DHCP, ICMP (Internet Control Message Protocol), UDP, TCP,

 

ARP)

 

Encapsulation over IP (tunneling) for serial async multidrop protocols,

 

including MODBUS, DNP.3, Bisync, BSAP, DF1, TotalFlow, Poll Select

Transceiver Management

 

Methods Supported (AP):

HTTP (embedded Web server)—pending

 

Telnet • Local console via COM1 port

 

SNMPv1/2/3. MIB II, Enterprise MIB—pending

 

SYSLOG

 

NETview MSTM—pending

Methods Supported (Remote):

Local console via COM1 port

Environmental

 

Temperature Range:

-40C to +70C (-33.8F to +158F)

Humidity:

95% at +40° C (104° F); non-condensing

Input Power:

6.0*–30VDC (13.8VDC nominal)

 

*Measured at the radio connector, not the source

Power Consumption:

7.05 Watts maximum at 1 Watt RF output (See below for details by model

 

and voltage)

Transmit:

 

900 MHz AP:

1175 mA at 6VDC 525 mA at 13.8VDC 270 mA at 30VDC

900 MHz Remote:

1025 mA at 6VDC 600 mA at 13.8VDC 240 mA at 30VDC

2400 MHz AP:

1091.7 mA at 6VDC 488.5 mA at 13.8VDC 253.3 mA at 30VDC

2400 MHz Remote:

941.7 mA at 6VDC 433.8 mA at 13.8VDC 223.3 mA at 30VDC

Receive:

 

900 MHz AP:

510 mA at 6VDC 220 mA at 13.8VDC 115 mA at 30VDC

900 MHz Remote:

260 mA at 6VDC 120 mA at 13.8VDC 65 mA at 30VDC

2400 MHz AP:

533.3 mA at 6VDC 230.1 mA at 13.8VDC 119.7 mA at 30VDC

2400 MHz Remote:

283.3 mA at 30VDC 130.1 mA at 13.8VDC 69.7 mA at 30VDC

Sleep (all remotes):

130 mA at 6VDC 15 mA at 12VDC 8 mA at 30VDC

Shutdown (all remotes):

0.37 mA at 6VDC

0.55mA at 12VDC

0.78mA at 30VDC

GFK-2489

Chapter 8 Technical Reference

8-13

Page 174