8

COM1 Port

A PC may be connected to the Remote transceiver COM1 port (RJ-12) for diagnostics and configuration.

COM1 Port (DCE)

(viewed from the outside of the radio)

Pin

Functions

COM1 Port (DCE)

1Unused

2Unused

3Unused

4

Receive Data (RXD)

Out

5

Transmit Data (TXD)

In

6

Ground

COM2 Port

A terminal device may be connected to the transceiver COM2 port (RJ-45) for payload data connection.

COM2 Port (DCE)

(viewed from the outside of the radio)

Pin

Functions

COM2 Port (DCE)

 

 

 

1

Unused

 

2

Data Carrier Detect (DCD)

Out

3

Data Terminal Ready (DTR) In

 

4

Signal Ground (GND)

5

Receive Data (RXD)

Out

6

Transmit Data (TXD)

In

7

Clear-to-Send (CTS)

Out

8

Request-to-Send (RTS)

In

GFK-2489

Chapter 8 Technical Reference

8-11

Page 172
Image 172
GE GFK-2489 user manual COM1 Port, COM2 Port