Table 2-11Jetdirect menus (continued)

Menu item

Sub-menu item

Sub-menu item

Values and Description

 

 

 

 

 

 

SNMP Test

This test checks operation of SNMP communications

 

 

 

by accessing predefined SNMP objects on the device.

 

 

 

Select Yes to choose this test, or No to not choose it.

 

 

 

 

 

 

Select All Tests

Use this item to select all available embedded tests.

 

 

 

Select Yesto choose all tests. Select No to select

 

 

 

individual tests.

 

 

 

 

 

 

Data Path Test

This test helps to identify data path and corruption

 

 

 

problems on an HP postscript level 3 emulation device.

 

 

 

It sends a predefined PS file to the device, However,

 

 

 

the test is paperless; the file will not print.

 

 

 

Select Yes to choose this test, or No to not choose it.

 

 

 

 

 

 

Execution Time [H]

Use this item to specify the length of time (in hours) that

 

 

 

an embedded test will be run. You can select a value

 

 

 

from 1 to 60 hours. If you select zero (0), the test runs

 

 

 

indefinitely until an error occurs or device is turned off.

 

 

 

Data gathered from the HTTP, SNMP, and Data Path

 

 

 

tests is printed after the tests have completed.

 

 

 

 

 

 

Execute

No*: Do not initiate the selected tests.

 

 

 

Yes: Initiate the selected tests.

 

 

 

 

 

Ping Test

 

This test is used to check network communications.

 

 

 

This test sends link-level packets to a remote network

 

 

 

host, then waits for an appropriate response. To run a

 

 

 

ping test, set the following items:

 

 

 

 

 

 

Dest Type

Specify whether the target device is an IPv4 or IPv6

 

 

 

node.

 

 

 

 

 

 

Dest IP

IPV4: Type the IPv4 address.

 

 

 

IPV6: Type the IPv6 address.

 

 

 

 

 

 

Packet Size

Specify the size of each packet, in bytes, to be sent to

 

 

 

the remote host. The minimum is 64 (default) and the

 

 

 

maximum is 2048.

 

 

 

 

 

 

Timeout

Specify the length of time, in seconds, to wait for a

 

 

 

response from the remote host. The default is 1 and

 

 

 

the maximum is 100.

 

 

 

 

 

 

Count

Specify the number of ping test packets to send for this

 

 

 

test. Select a value from 1 to 100. To configure the test

 

 

 

to run continuously, select 0.

 

 

 

 

 

 

Print Results

If the ping test was not set for continuous operation,

 

 

 

you can choose to print the test results. Select Yes to

 

 

 

print results. If you select No (default), results are not

 

 

 

printed.

 

 

 

 

 

 

Execute

Specify whether to initiate the ping test. Select Yes to

 

 

 

initiate the test, or No to not run the test.

 

 

 

 

ENWW

Use the Administration menu 33