2.Open the ADF cover.

3.Press the round blue button while lifting the green lever. Rotate the green lever until it stops in the open position. The pickup roller assembly should remain on the surface.

4.Remove the assembly, and then wipe the assembly with a soft, dry, lint-free cloth.

5.Replace the assembly, with the largest roller down, in the upright holder, and then press until the assembly snaps into place.

142 Chapter 10 Manage and maintain the device

ENWW

Page 154
Image 154
HP M3027/M3035 manual Enww