Removing Internal Drives

Note: Before you hot-swap a drive, make sure it is defective. If you partially or completely remove a good drive instead of a defective one, your server might lose valuable data.

This situation is especially relevant if you have a RAID adapter installed and you assigned RAID level 1 or 5 to the logical drives in your disk array. However, the RAID adapter can rebuild the data that you need, provided that certain conditions are met. Refer to the RAID adapter documentation for further details.

Table 6 describes the lights that indicate the status of the hard disk drives in the server.

Table 6. Hard Disk Drive Status Indicators

Indicator

State

Description

Light

 

 

 

 

 

Hard Disk

Continuously

Hot-swap drive is present. Power

Power-On

on (green)

is being applied to the drive.

 

 

 

Hard Disk

Flashing

Hot-swap drive activity is

In-Use

(green)

occurring. Data is being read

 

 

from or written to the drive.

 

 

Power is being applied to the

 

 

drive.

 

 

 

Hard Disk

Continuously

Hot-swap drive has a fault. The

Fault

on (amber)

indicator light stays on until the

 

 

RAID adapter clears it.

 

 

 

Hard Disk

Flashing

Rebuild is in process. Do not

Fault

(amber)

remove the drive.

 

 

 

Note: When the indicator light indicates a drive fault, you can replace a hot-swap drive without turning off the server.