POST Error Messages

POST Message

Description

0043

The EISA configuration is not valid for the slot.

 

Action: Start the System Configuration Utility and check for

 

conflicts. If the problem recurs, have the system

 

serviced.

 

 

0044

The EISA configuration is not assured!

 

Action:

 

Ÿ If you have just added, removed, or changed the

 

location of an EISA or an ISA adapter, start the

 

System Configuration Utility and update the

 

configuration information. If the problem recurs,

 

have the system serviced.

 

Ÿ If you have not just added, removed, or changed

 

the location of a device, run the test programs to

 

identify the failing device. Then have the system

 

serviced.

 

 

0045

The EISA expansion board is not ready in the slot.

 

Action: Reseat the expansion board. If the problem recurs,

 

have the system serviced.

 

 

0047

The EISA CMOS configuration is not set.

 

Action:

 

Ÿ If you have just added, removed, or changed the

 

location of an EISA or an ISA adapter, start the

 

System Configuration Utility and update the

 

configuration information. If the problem recurs,

 

have the system serviced.

 

Ÿ If you have not just added, removed, or changed

 

the location of a device, run the test programs to

 

identify the failing device. Then have the system

 

serviced.

 

 

0048

An error occurred in the EISA checksum.

 

Action: Turn off the system and wait 30 seconds; then, turn it

 

back on. If the problem recurs, have the system

 

serviced.

 

 

0049

The EISA NVRAM is invalid.

 

Action: Turn off the system and wait 30 seconds; then, turn it

 

back on. If the problem recurs, have the system

 

serviced.

 

 

Chapter 5. Solving Problems 233