POST Error Messages

POST Message

Description

0195

The CMOS system options have not been set.

 

Action:

 

Ÿ If you have just replaced the real-time clock on the

 

system board, start the Setup program to set the

 

correct date and time. If the problem recurs, have

 

the system serviced.

 

Ÿ If you have not just removed or replaced the

 

real-time clock, have the system serviced.

 

 

0198

The CMOS checksum is invalid.

 

Action: Have the system serviced.

 

 

0289

A change in the memory configuration occurred. Installing

 

memory incorrectly, such as not installing memory modules

 

in matched sets, can cause this problem. It can also occur if a

 

memory module is defective.

 

Action: Ensure that the memory modules are installed

 

properly (see “Installing Memory-Module Kits” on

 

page 113). If the modules are properly installed, run

 

the test programs to determine the cause of the

 

problem and the action to take. If the test programs do

 

not find the problem, have the system serviced.

 

 

0295

Address Line Short Detected.

 

Action: Have the system serviced.

 

 

0297

The memory size has decreased.

 

Action:

 

Ÿ If you have just removed memory from the server,

 

start the System Configuration Utility. Save the

 

new configuration information; then, restart the

 

server. If the problem recurs, have the server

 

serviced.

 

Ÿ If you have not just removed memory, have the

 

server serviced.

 

 

0299

ECC Error Correction failed.

 

Action: Turn off the system and wait 30 seconds; then, turn it

 

back on. If event logging is enabled, POST logs this

event in nonvolatile flash memory. If the problem recurs, have the system serviced.