IBM 704 manual Power-Good Light PS Current-Good Light Description

Models: 704

1 348
Download 348 pages 7.22 Kb
Page 31
Image 31

Padlock Loops: The two side cover padlock loops enable you to insert padlocks (not provided) to secure the side covers to the system unit.

The electro-magnetic interference (EMI) door on the front of the server also has a padlock loop. You can insert a small padlock (not included) through this loop to secure the EMI door to the system unit and help prevent unauthorized access to the hard disk drives in the hot-swap bays.

Power Supplies: All PC Server 704 models support three 420-watt power supplies. In a three-supply system, the third power supply provides redundant power.

9

CAUTION:

Power supplies are easy to install and remove, but they are not hot-swappable. Always disconnect all server power cords and all power supply power cords before you remove or install a power supply.

Power-Good Light and Current-Good Light: These green lights

provide status information about the power supply, as follows:

Power-Good Light (PS)

Current-Good Light (I)

Description

 

 

 

On

On

Power supply on and

 

 

OK

 

 

 

Off

Off or On

Power supply failure

 

 

 

On

Off

Current limit

 

 

 

Note: To ensure that the power supply is operational, both lights must be on.

Chapter 1. Introducing the PC Server 704 13

Page 31
Image 31
IBM 704 manual Power-Good Light PS Current-Good Light Description