This soft copy for use by IBM employees only.
STATUS mandatory
DESCRIPTION
The called number carried in the called party number
information element of the call set-up message.
::= { atmSvcLogEntry 4 }
atmSvcLogCreationTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
The date and time this call was placed.
::= { atmSvcLogEntry 5 }
atmSvcLogTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
The date and time this call was cleared.
::= { atmSvcLogEntry 6 }
atmSvcLogClearCause OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
The cause of the clearing of this SVC.
REFERENCE
ATM Forum/93-265R5 Signalling Specification Draft -
Apr. 14, 93.
::= { atmSvcLogEntry 7}
atmSvcLogForwardQOS OBJECT-TYPE
SYNTAX INTEGER {
-- unspecified (0),
class-A (1),
class-B (2),
class-C (3),
class-D (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
The forward Quality Of Service requested for this
call.
::= { atmSvcLogEntry 8}
atmSvcLogBackwardQOS OBJECT-TYPE
SYNTAX INTEGER {
-- unspecified (0),
class-A (1),
class-B (2),
class-C (3),
class-D (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
238 ATM Workgroup Solutions: Implementing the 8285 ATM Switch